088 HPM 1115

HPM November 2015

Got a story? Ring us on 01732 748041 or e-mail twood@unity-media.com WATERHEATING,TANKS&CYLINDERS Unvented cylinders: pay close attention When choosing an unvented cylinder, it’s important to opt for a well-made, high-quality, efficient product otherwise the result might be a disappointed customer and costly, time consuming call backs. Jon Cockburn, head of marketing at Heatrae Sadia, shares his top product selection tips... In recent years, an increasing number of manufacturers have brought unvented hot water cylinders to market to capitalise on the demand for high pressure, high-performance hot water. On face value all unvented cylinders might look the same, but closer inspection will reveal important differences. So, it is, therefore, worth comparing what’s on offer, as underperforming products will lead to disappointed customers. The key things to consider are materials, energy efficiency, performance, product approvals and warranties. MATERIALS As unvented cylinders store water under pressure, it is essential that they are strong, durable and corrosion resistant. In the UK, cylinders are generally made from stainless steel, copper or glass lined mild steel. Cylinders made from mild steel will, however, require a coating or glass lining to make them corrosion resistant. They also need a sacrificial anode, as do some cylinders made from low-grade stainless steel. The anode will need to be monitored for signs of erosion each year. Duplex stainless steel is by far the preferred material in the manufacture of unvented cylinders, as it has outstanding corrosion resistant properties. It is also lightweight, giving it a strength-to-weight ratio advantage. We pioneered the use of Duplex stainless steel, and for longer cylinder life we use a combination of laser and TIG welding and butt joints to avoid crevices, and carry out comprehensive, state-of-the-art post weld treatments. It’s not just the material that the internal cylinder is made from that’s important. On a direct cylinder, a titanium immersion heater is a good indicator of quality and on an indirect cylinder the material to look for would be Superloy 825. Both are high-grade, but the immersion heater on a direct cylinder needs to be made from a stronger material, as it will be used more frequently than on an indirect model, where the immersion acts as a back-up. ENERGY EFFICIENCY Manufacturers also invest in research and development to ensure their products are energy efficient to meet the needs of today’s installers and end users. From September 26 this year, it has been easier to compare efficiencies, thanks to the energy labels that now apply to water heaters with outputs of up to 70kW and hot water storage tanks with storage volumes of up to 500 litres. WWW.HPMMAG.COM The energy efficiency bands featuring on the labels initially range from A to G, but will eventually extend to A+++ and band G will be removed in 2017. As well as stating the energy efficiency band, directly heated water heaters also include a size (load) profile, ranging from 3XS to 4XL. To provide a few examples, 3XS would be a water heater typically suitable for a small single basin at 35ºC, S would be for a shower and single basin at 35ºC, M would be for showers and a sink at 55ºC, L would be for a bath, shower and sink at 55ºC and XXL would be for simultaneous baths and showers. Manufacturers of all water heaters and hot water storage tanks in the scope of the Energy related Products Directive also have to provide additional performance and efficiency parameters via a ‘technical fiche’ and within product data, which must be included on company websites and in installation instructions. Energy labelling will make product efficiencies clearer, but it will be important to refer to these technical fiches as well; they will be particularly invaluable when water heating products in the same band are being compared against one another. PERFORMANCE Market leading brands will also invest in the performance of their products, whether that’s by improving flow rates, recovery times, the amount of stored hot water available or standing heat losses – and this can all be researched and assessed via manufacturers’ literature and recommendations. To provide a few examples of what we do differently. We insulate Megaflo Eco’s T&P valve 88 NOVEMBER 2015 HEATING & PLUMBING MONTHLY to reduce heat loss, and use an L shaped heating element rather than a straight one to ensure the whole cylinder is heated and a patented inlet diffuser that ensures excellent stratification and hot water output. PRODUCT APPROVALS To ensure a product has been properly Upgrading an old cylinder will result in huge savings manufactured, is built to last and will operate safely, installers should look out for hot water cylinders that are constructed and tested to established British and European standards, as well as being manufactured in a factory which has accredited Quality Management Systems. Third party approvals – such as from WRAS and KIWA – demonstrate good quality and performance. WARRANTIES Customers will expect their new hot water cylinder to have a long and reliable life, so ensuring the product has an extended or comprehensive warranty will offer peace of mind that should anything go wrong, they will be covered. Installers should check the terms of any warranty offered, and any limitations hidden in the T&Cs. Particular things to be aware of are whether onsite parts and labour costs are included, whether the warranty is transferrable to new owners if the property is sold, and what the level of support offered is like, for example, it’s worth looking at the size of the call centre, the opening hours and the level of engineer coverage across the UK. All unvented cylinders might initially seem the same, but there will be important differences between brands. High-quality products offer the best possible performance, efficiency and innovation and good value for money, and will ensure customer satisfaction in the long run. enquiry number 144 Heatrae’s cylinders are established to British and European standards


HPM November 2015
To see the actual publication please follow the link above